Investigation of <i>Legionella</i> and Other Pathogenic Microorganisms in Different Departments of a University Hospital: A Prospective Study
PDF
Cite
Share
Request
Original Research
P: 81-90
March 2022

Investigation of Legionella and Other Pathogenic Microorganisms in Different Departments of a University Hospital: A Prospective Study

J Turk Soc Intens Care 2022;20(1):81-90
1. Kahramanmaraş Sütçü İmam Üniversitesi Tıp Fakültesi, Tıbbi Mikrobiyoloji Anabilim Dalı, Kahramanmaraş, Türkiye
2. Kahramanmaraş Sütçü İmam Üniversitesi Tıp Fakültesi, Mikrobiyoloji Anabilim Dalı, Kahramanmaraş, Türkiye
3. Kahramanmaraş Sütçü İmam Üniversitesi Tıp Fakültesi, Anesteziyoloji ve Reanimasyon Anabilim Dalı, Kahramanmaraş, Türkiye
4. Kahramanmaraş Sütçü İmam Üniversitesi Tıp Fakültesi, Anesteziyoloji ve Reanimasyon Anabilim Dalı, Kahramanmaraş, Türkiye
No information available.
No information available
Received Date: 03.01.2022
Accepted Date: 23.05.2022
Publish Date: 20.09.2022
PDF
Cite
Share
Request

ABSTRACT

Objective:

In this study, it was aimed to investigate Legionella spp. and other pathogenic microorganisms in swab samples taken from different units of a tertiary healthcare hospital between July 25, 2019 and November 1, 2019.

Materials and Methods:

Ninety-two swab samples were taken from the mechanical ventilator, air conditioner filters, water outlets, and sink faucets in the laboratory, operating room and different intensive care units of the hospital. All samples were centrifuged and inoculated directly onto buffered coal yeast extract agar, a medium selective for Legionella and other conventional media. 16S rRNA sequence analysis was performed for identification at the species level by randomly selecting 6 samples that were positive for Legionella by culture and serological tests.

Results:

Growth compatible with Legionella spp. colonies was observed in 24 (26.08%) cultures. Only three of the 6 serogrouped samples were confirmed by molecular identification. Two of these were identified as Legionella pneumophila subsp. pneumophila and the other as Legionella anisa. Penicillium spp., Aspergillus flavus, Acinetobacter baumannii, Morganella morganii, Moraxella spp., and Pseudomonas aeruginosa were isolated from the filters of mechanical ventilators and Escherichia coli from a tap sample.

Conclusion:

Potential Legionella spp. exposure in high-risk patients should be eliminated with increased sampling frequency and effective control measures.

Keywords: Legionella spp., pathogen, identification, 16S rRNA

References

1
Mérault N, Rusniok C, Jarraud S, Gomez-Valero L, Cazalet C, Marin M, et al. Specific real-time PCR for simultaneous detection and identification of Legionella pneumophila serogroup 1 in water and clinical samples. Appl Environ Microbiol 2011;77:1708-17.
2
Collier SA, Stockman LJ, Hicks LA, Garrison LE, Zhou FJ, Beach MJ. Direct healthcare costs of selected diseases primarily or partially transmitted by water. Epidemiol Infect 2012;140:2003-13.
3
Kireçci E, Dağlı S. Kahramanmaraş İlindeki Camilerin Klima ve Şadırvanlarından Legionella Cinsi Bakterilerin İdentifikasyonu. Duzce Univ Saglik Bilim 2019;9:6-9.
4
Burak DM, Zeybek Z. İstanbul’daki evlerin sıcak su sistemlerinde Legionella pneumophila ve özgür yaşayan amiplerin araştırılması. Turk J Biol 2011;35:679-85.
5
Lasheras A, Boulestreau H, Rogues AM, Ohayon-Courtes C, Labadie JC, Gachie JP. Influence of amoebae and physical and chemical characteristics of water on presence and proliferation of Legionella species in hospital water systems. Am J Infect Control 2006;34:520-5.
6
Asghari FB, Nikaeen M, Hatamzadeh M, Hassanzadeh A. Surveillance of Legionella species in hospital water systems: the significance of detection method for environmental surveillance data. J Water Health 2013;11:713-9.
7
Kim BR, Anderson JE, Mueller SA, Gaines WA, Kendall AM. Literature review--efficacy of various disinfectants against Legionella in water systems. Water Res 2002;36:4433-44.
8
Murdoch DR. Diagnosis of Legionella infection. Clin Infect Dis 2003;36:64-9.
9
Standard B. Microbiological methods, detection and enumeration of Legionella. Water Quality part 4 BS 6068- 412, ISO 11731 London: British Standards Institution; 1998.
10
Marmur J. A procedure for the isolation of deoxyribonucleic acid from micro-organisms. J Mol Biol 1961;3:208-18.
11
Lane DJ. 16S/23S rRNA sequencing. In: Stackebrandt E GM, editor. Nucleic acid techniques in bacterial systematics. New York: Wiley; 1991. p. 115-75.
12
Clinical Laboratory Standards Institute. Interpretive Criteria for Identification of Bacteria and Fungi by Targeted DNA Sequencing, MM18. In: Institute CLaS, editor. 2nd ed: Clinical and Laboratory Standards Institute, MM18; 2018.
13
Tamura K, Nei M. Estimation of the number of nucleotide substitutions in the control region of mitochondrial DNA in humans and chimpanzees. Mol Biol Evol 1993;10:512-26.
14
T.C. Sağlık Bakanlığı Türkiye Halk Sağlığı Kurumu. Lejyoner Hastalığının Mikrobiyolojik Tanısı, UMS-B-MT-06. Ulusal Mikrobiyoloji Standartları, Bulaşıcı Hastalıklar Laboratuvar Tanı Rehberi 934. Ankara: Sağlık Bakanlığı Yayın 2014.
15
Sakhaee F, Mafi S, Zargar M, Vaziri F, Hajiesmaeili M, Siadat SD, et al. Correlation between Legionella pneumophila serogroups isolated from patients with ventilator-associated pneumonia and water resources: a study of four hospitals in Tehran, Iran. Environ Sci Pollut Res Int 2022;29:41368-74.
16
World Heath Organization. Legionella and the prevention of legionellosis. Geneva: World Health Organization; 2007.
17
Dooling KL, Toews KA, Hicks LA, Garrison LE, Bachaus B, Zansky S, et al. Active Bacterial Core Surveillance for Legionellosis - United States, 2011-2013. MMWR Morb Mortal Wkly Rep 2015;64:1190-3.
18
Kusnetsov JM, Martikainen PJ, Jousimiessomer HR, Vaisanen ML, Tulkki AI, Ahonen HE, et al. Physical, Chemical and Microbiological Water Characteristics Associated with the Occurrence of Legionella in Cooling-Tower Systems. Water Res 1993;27:85-90.
19
Erdogan H, Arslan H. Colonization of Legionella species in Turkish baths in hotels in Alanya, Turkey. Environ Monit Assess 2015;187:235.
20
Edagawa A, Kimura A, Doi H, Tanaka H, Tomioka K, Sakabe K, et al. Detection of culturable and nonculturable Legionella species from hot water systems of public buildings in Japan. J Appl Microbiol 2008;105:2104-14.
21
Torres A, Cilloniz C, Niederman MS, Menéndez R, Chalmers JD, Wunderink RG, et al. Pneumonia. Nat Rev Dis Primers 2021;7:25.
22
Leoni E, De Luca G, Legnani PP, Sacchetti R, Stampi S, Zanetti F. Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems. J Appl Microbiol 2005;98:373-9.
23
Borella P, Montagna MT, Stampi S, Stancanelli G, Romano-Spica V, Triassi M, et al. Legionella contamination in hot water of Italian hotels. Appl Environ Microbiol 2005;71:5805-13.
24
Centers for Disease Control and Prevention. Legionella Water Management Programs Overview. Available from: URL: https://www.cdc.gov/legionella/wmp/overview.html. Accessed April 12, 2022.
25
Alim A DTZ, Ataş AD, Güneş T. Investigation of Legionella spp. from the Turkish baths in Sivas. J Microbiol Infect Dis 2007;12:103-7.
26
Cloud JL, Carroll KC, Pixton P, Erali M, Hillyard DR. Detection of Legionella species in respiratory specimens using PCR with sequencing confirmation. J Clin Microbiol 2000;38:1709-12.
27
Pierre DM, Baron J, Yu VL, Stout JE. Diagnostic testing for Legionnaires’ disease. Ann Clin Microbiol Antimicrob 2017;16:59.
28
Taylor MJ, Bentham RH, Ross KE. Limitations of Using Propidium Monoazide with qPCR to Discriminate between Live and Dead Legionella in Biofilm Samples. Microbiol Insights 2014;7:15-24.
29
Unterberg M, Rahmel T, Kissinger T, Petermichl C, Bosmanns M, Niebius M, et al. Legionella contamination of a cold-water supplying system in a German university hospital - assessment of the superheat and flush method for disinfection. J Prev Med Hyg 2021;62:E751-8.
30
Mouchtouri VA, Goutziana G, Kremastinou J, Hadjichristodoulou C. Legionella species colonization in cooling towers: risk factors and assessment of control measures. Am J Infect Control 2010;38:50-5.
31
Cervero-Aragó S, Sommer R, Araujo RM. Effect of UV irradiation (253.7 nm) on free Legionella and Legionella associated with its amoebae hosts. Water Res 2014;67:299-309.
32
Boss R, Baumgartner A, Kroos S, Blattner M, Fretz R, Moor D. Rapid detection of viable Legionella pneumophila in tap water by a qPCR and RT-PCR-based method. J Appl Microbiol 2018;125:1216-25.
2024 ©️ Galenos Publishing House