Bilateral Pneumothorax during Apnea Test: A Case Report and Literature Review
PDF
Cite
Share
Request
Case Report
P: 39-42
April 2017

Bilateral Pneumothorax during Apnea Test: A Case Report and Literature Review

J Turk Soc Intens Care 2017;15(1):39-42
1. Atatürk Üniversitesi Tip Fakültesi, Anesteziyoloji Ve Reanimasyon Anabilim Dali, Erzurum, Türkiye
2. Bölge Egitim Ve Arastirma Hastanesi, Anestezi Klinigi, Erzurum, Türkiye
3. Igdir Devlet Hastanesi, Anestezi Klinigi, Igdir, Türkiye
No information available.
No information available
Received Date: 09.11.2015
Accepted Date: 24.01.2016
PDF
Cite
Share
Request

ABSTRACT

Brain death is characterized by irreversible loss of all brain functions and it is defined as a clinical condition where intracranial circulation stops. Apnea test is one of the tests which is used in the clinical diagnosis of brain death, absence of brain stem reflexes, and as a complement to absence of motor response to painful stimulants. Apnea test is a test which has a high complication rate. Complications such as hypoxia, hypotension, acidosis, cardiac arrhythmia, asystole, pneumothorax, pneumomediastinum and pneumoperitoneum may develop during an apnea test. In this case report, a patient with biletarel pneumothorax due to air trapping because of an oxygen cannula blocking the airway.